Reverse Osmosis is a process where water is demineralised using a semi permeable membrane at high pressure. Your normal filtration units will only reduce certain contaminants such as silt, rust, chlorine and bacteria (up to 96%). Reverse Osmosis machines will purify your water up to 99.9% or 0.001 microns, thus removing other dissolved contaminants like Colloid, lead, mercury, germs and other metals.
Stage 1 : Polypropylene Cartridge – 5 Micron Superfine Filter – Removes solid particles & impurities i.e. silt & rust.
Stage 2 : Granular Activated Carbon (UDF) Filter – Absorbs odours, chemicals & chlorine.
Stage 3 : Carbon Block Filter (CTO) – removes additional chlorine & water decolourants.
Stage 4 : Reverse Osmoses Membranes – Removes up to 0.0001 microns colloid, metals, germs & bacteria.
Stage 5 : Post Carbon Filter (T33) – improves water taste.
If your water pressure is above 6 bar you will need a pressure reducing valve to keep your pressure within the operating pressure limits.
We recommend that a plumber install the unit as a pressure reducing valve may be required.
You can replace the 100GPD membranes with 125GPD membranes to get up to 500GPD/1900LPD from this unit.
Stage 1 : Polypropylene Cartridge – 5 Micron Superfine Filter – Removes solid particles & impurities i.e. silt & rust.
Stage 2 : Granular Activated Carbon (UDF) Filter – Absorbs odours, chemicals & chlorine.
Stage 3 : Carbon Block Filter (CTO) – removes additional chlorine & water decolourants.
Stage 4 : Reverse Osmoses Membranes – Removes up to 0.0001 microns colloid, metals, germs & bacteria.
Stage 5 : Post Carbon Filter (T33) – improves water taste.
If your water pressure is above 6 bar you will need a pressure reducing valve to keep your pressure within the operating pressure limits.
- This unit produces up to 400 Gallons or 1500 litres every 24 hours.
- This unit has two pumps, an electrical outlet is required nearby.
- This unit has four VONTRON 100GPD membranes.
- This unit includes a 40LT RO Storage Tank and a Standard Elegant RO Faucet (not shown in picture).
- This unit can be modified with a float switch to fill up larger tanks, such as JoJo Tanks, as seen in this photo.
We recommend that a plumber install the unit as a pressure reducing valve may be required.
You can replace the 100GPD membranes with 125GPD membranes to get up to 500GPD/1900LPD from this unit.
- Item Code: RO400GPD