Ultrafiltration
Ultrafiltration will not remove Chlorine and other chemicals or dissolved content, it is recommended to use UF with pre-filtration of activated carbon.




On-demand purified water with this dual stage in-line filtration system which is installed under the counter/sink with the faucet mounted into the counter/sink.
Unlike Reverse Osmosis, this unit does not remove the existing minerals from the water and does not waste any water, it is superior to standard filtration as the UF membrane removes all particles larger than 0.01 micron including bacteria.
- Premium Three-Stage 10 inch Under-Counter Filtration System.
- Chrome Plated Faucet.
- Pipes included (as illustrated in image).
- Ultra-filtration Membrane.
- Up to 95% Chlorine reduction.
- Pure drinking water.
- Unit can handle up to 6 bars of pressure however, 4 bar is the recommended maximum.
Unsure of your water pressure? We recommend purchasing the optional pressure reducing valve to further reduce risk of leakage, it is not uncommon for water pressure to surge which is why we recommend using the pressure reducing valve if your water pressure is over 4 Bars.
*Note: Faucet may differ to image if option not selected.
This unit is installed under the counter with the faucet mounted into the counter.
Stage 1: Sediment filter down to 5um.
Stage 2: Granular Activated Carbon, reduces Chlorine, heavy metals and odours while improving taste.
Stage 3: Activated Carbon Block, further reduces Chlorine, heavy metals and odours.
Stage 4: Ultra-filtration Membrane, Removes particles larger than 0.01 including bacteria and viruses.
Stage 5: Post Carbon Filter, further reduces Chlorine, heavy metals and odours.
- Five Stage 10 Inch Under-Counter Filtration System.
- Does not remove healthy minerals from the water.
- Luxury chrome faucet with ceramic swivel (not shown in image).
- Pipe, 1/2" adapter and ball valve included (not shown in image).
- Up to 98% Chlorine & Sediment reduction.
- Pure drinking water.
- Unit can handle up to 6 bars of pressure.
- Housings have a double o-ring design to reduce risk of leaks.
- No waste water.
Filters to be changed once a year.
- Maximum feed pressure ( Mpa ) 0.3
- Admission Transmembrane Pressure ( MPa ) 0.3
- Normal operation pressure ( MPa ) 0.1 ~ 0.3
- Backwash pressure ( MPa ) 0.1
- Ph value of feed water 2 – 10
- Chlorine of feed water (mg/L) < 3
- Operation mode Dead end or Cross-flow
- Max operating temperature < 45°C
- Membrane characteristics Hydrophilic Double Skin
- Hollow-fiber membrane material Polyacrylonitrile (PAN) Modified
- MWCO (Dalton) 50,000
- Membrane area (m2) 5
- In & out water caliber of membrane module G 3/4”
- Max Air Pressure for integrity test (MPa) 0.2
- Flux (0.1MPa, 25° C) 4000 Liters /Hour
- Material of Cartridge ABS
- Weight of Cartridge with hollow fiber <15KG
- Time to change cartridge 1-2 years
- Material of cylinder housing Stainless Steel 304
- Thickness of housing 1.5 mm
Note: These specs are tested under conditions of (1) stable water pressure (2) stable quality of feed water and Maintenance. Some of the performances may differ if not fulfilled the above conditions.
Clean water comes out the side port, either end is the inlet and the other end should be blocked off.
You cannot use UF without sufficient pre-filtration.
NOTE: These systems are rated at 4,000LPH however this depends on pre-treatment and having sufficient supply and pressure to provide 4,000LPH at 3BAR to the membrane, from our own experience without supplying 4,000LPH at 3BAR with adequate pre-filtration you will not receive this volume and may need more units in parallel configuration to achieve this.


PLEASE BE ADVISED THIS ITEM IS ON BACK ORDER AND WE DO NOT HAVE AN ETA AS OF YET.
- 1