Vontron
- Fits in standard 1.8" x 12" residential RO membrane housings.
VONTRON® Residential Membrane Elements
Brief Introduction
Being suitable for the desalting treatment of those water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series are mainly applicable to numerous applications of various sizes, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.
Specifications and Major Properties
Average Permeated Flow: 50 GPD
Stable Rejection Rate: 97.5%
Minimum Rejection Rate: 96.0%
Testing Conditions:
Temperature of Testing Solution 25°C
Concentration of Testing Solution (NaCl) 250ppm
pH Value of Testing Solution 7.5
Recovery Rate of Single Membrane Element 15%
Extreme Operation Conditions:
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Free Chlorine Concentration of Feedwater <0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 10psi(0.07Mpa)
Important Information
2. The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding ±20% of the nominal value.
3. All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanediol required in winter) for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation and system standby, we recommend you to soak the membrane elements with protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfite (foodstuff-purpose).
4. Discard the RO-filtered water produced during the first one hour after system start-up.
5. During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful.
Specifications
3.Average Permeate GPD(m3/d): 100(0.38)
4.Pressure psi(Mpa): 100(0.69)
5.Pecovery Rate(%): 15
Brief Introduction
The 1812-sized and 2012-sized residential membrane elements are mainly applicable to various small-sized systems, such as household water purifier and other water purifying devices in hospital and laboratory.
Specifications and Major Properties
Model | Active Membrane Area ft2(m2) | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
ULP2812 | 11.2(1.04) | 200(0.76) | 97 | 95.5 |
ULP3012 | 13.2(1.23) | 240(0.91) | 97 | 95.5 |
UL3020 | 24.1(2.24) | 420(1.60) | 97 | 95.5 |
Testing Conditions: Testing Pressure………………………………………………100 psi (0.41Mpa)
Temperature of Testing Solution ………………… 25 °C
Concentration of Testing Solution (NaCl)……… 500ppm
pH Value of Testing Solution ……………………………7.5
Recovery Rate of Single Membrane Element……15%
Extreme Operation Conditions
Max. Working Pressure…………………………………………………………… 300psi(2.07Mpa)
Max. Feedwater Temperature……………………………………………… 45°C
Max. Feedwater SDI………………………………………………………………… 5
Residual chlorine Concentration of Feedwater……………………… <0.1ppm
pH Range of Feedwater during Continuous Operation………… 3~10
pH Range of Feedwater during Chemical Cleaning……………… 2~12
Max. Pressure Drop of Single Membrane Element………………… 10psi(0.07Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
- Model: ULP21-4040
- Reject: 99.0%
- Average Permeate GPD(m3/d): 2400(9.1)
- Active Membrane Area ft2(m2): 90(8.4)

Model
|
Active Membrane Area
ft2(m2)
|
Average Permeated Flow
GPD (m3/d)
|
Stable Rejection Rate (%)
|
Minimum Rejection Rate (%)
|
ULP1812-50
|
3.5(0.32)
|
50(0.19)
|
97.5
|
96.0
|
ULP1812-75
|
4.2(0.38)
|
75(0.28)
|
97.5
|
96.0
|
ULP2012-100
|
5.0(0.46)
|
100(0.38)
|
95.0
|
93.0
|

- 1