NOTICE

Please be advised our Payfast integration is not currently working and EFT is the only payment option available during checkout, you can pay with credit or debit cards through our Yoco alternative gateway here until our Payfast integration is fixed, please use your order number as payment reference. Thank you

VONTRON 100GPD Reverse Osmosis Membrane

1812 Size.
R569.25
Qty:
VONTRON® Residential Membrane Elements
Brief Introduction
The 1812-sized residential membrane elements are mainly applicable to various small-sized systems, such as household water purifiers and other water purifying devices in hospitals and laboratories.
 Being suitable for desalinization systems and water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series are mainly applicable to numerous applications of various sizes, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.
 
Specifications and Major Properties
Model
Active Membrane Area
ft2(m2)
Average Permeated Flow
GPD (m3/d)
Stable Rejection Rate (%)
Minimum Rejection Rate (%)
ULP1812-50
3.5(0.32)
50(0.19)
97.5
96.0
ULP1812-75
4.2(0.38)
75(0.28)
97.5
96.0
ULP1812-100
5.0(0.46)
100(0.38)
95.0
93.0
 
Testing Conditions:  Testing Pressure…………………………………60 psi (0.41Mpa)
                                     Temperature of Testing Solution …………..…25 ℃
                                     Concentration of Testing Solution (NaCl)…….. 250ppm
                                     pH Value of Testing Solution ……………….….7.5
                                     Recovery Rate of Single Membrane Element….15%
Extreme Operation Conditions
Max. Working Pressure…………………...…….……….  300psi(2.07Mpa)
Max. Feedwater Temperature…………………….………   45℃
Max. Feedwater SDI………………….………………….. 5
Free Chlorine Concentration of Feedwater………………     <0.1ppm
pH Range of Feedwater during Continuous Operation…..      3~10
pH Range of Feedwater during Chemical Cleaning……...      2~12
Max. Pressure Drop of Single Membrane Element…….        10psi(0.07Mpa)
 
Sizes are in mm (inch in brackets).
 
Important Information
1.         Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, Vontron technology Co., Ltd. will assume no liability for all results.
2.         The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding ±20% of the nominal value.
3.        All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanediol required in winter) for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation and system standby, we recommend you to soak the membrane elements with protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfite (foodstuff-purpose).
4.       Discard the RO-filtered water produced during the first one hour after system start-up.
5.       During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful<

 


  • Item Code: RO-MEM100
  • Manufacturer: Vontron

    Vontron

Write Review

Note: Do not use HTML in the text.
  

Installation Services

We provide installation services on equipment we sell in East London & Port Elizabeth. For more information please see the Installation Services page.