Accessories

Fittings, Faucets and other Addons/Accessories.

Sort By:  
Used to shut off RO pump if supply pressure is too low.
Add to Cart
R100.50
Used to electronically open and shut off the flow of water.
Add to Cart
R1,552.50
Used to shut off RO pump when tank full.
Add to Cart
R98.85
RO Membrane Housing Wrench
Used to tighten and loosen RO membrane housings.
Add to Cart
R42.00
RO Booster Pump Gi-An GMB78
24V DC Working: 28LPH 81PSI for 50-100GPD RO System including Transformer.
Add to Cart
R1,664.48
20
Spanner to tighten and loosen filter housings.
Add to Cart
R42.00
Leak Detector
Automatically shuts off the water supply if a leak is detected.
Add to Cart
R402.50
RO Booster Pump
Used in 50GPD-100GPD Systems.
Add to Cart
R867.20
Low Pressure Switch for RO (RO-PSL)
Used to shut off RO pump if supply pressure is too low. Normally Closed.
Used to shut off RO pump if supply pressure is too low.
Add to Cart
R100.50
Quick Connect Ball Valve 1/4" Tube/Tube (QC-TB-BV-14)

Plastic Ball Valve with 1/4" DCC Fittings.

Used to control flow, also used in reverse osmosis for flushing of membrane.

Add to Cart
R43.70
1/4
1/4" Straight Connector Nipple (RO-NIP14)

1/4" Male Thread to 1/4" Male Thread Connector

Also called a Nipple or an RO Nipple.

Commonly used to join 1/4" filter housings.

** Current stock are the top ones with o-rings in the second picture and are made from nylon.

Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/4" is 12.9mm.

Add to Cart
R14.12
Drain Clamp
Drain Saddle Clamp (DSC)

Used to neatly insert RO 1/4" waste water tubing line into a drain pipe.

Add to Cart
R57.50
Brass Solenoid 220V AC (ROSOL)
Used with commercial and industrial reverse osmosis systems or custom applications.

  • Body Material: Brass
  • Pressure Max: 12 BAR
  • Input: 220V AC
  • Max Temperature: 80c

*** May differ to image due to multiple suppliers and models.


Used to electronically open and shut off the flow of water.
Add to Cart
R1,552.50
Quick Connect Elbow 1/4" to 1/8" Thread (QC-TB90-1418)

1/4" (6mm) Tubing Elbow to 1/8" Male Thread.

Typically used with Reverse Osmosis (RO) systems for inlet and waste out, fits most standard membrane housings.
Blue retaining clip not shown in image but is included.

Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/8" is 9.9mm.

Add to Cart
R25.20
High Pressure Switch for RO (RO-PSH)
Used to shut off RO pump when tank full.

  • Normally Closed.

*Note: The optional "1/4" Female Thread (Black) 15A" can be used with two of the 1/4" Thread to 3/8" Tubing Adapters for use with 300GPD and up RO units.
Used to shut off RO pump when tank full.
Add to Cart
R98.85
Venturi
Venturi for Ozone Injection 3/4" (OZ-VENT)
Highly efficient and compact differential pressure injection device.

Applications:
Ozone Injection, fertilizer and chemical injection through drip and sprinkler irrigation systems.

A venturi is a device which creates a vacuum when fluid flows through it. The fluid which creates the vacuum is known as the motive fluid. The motive fluid for irrigation injectors is the irrigation water itself. Vacuum created by the venturi sucks fertilizer or chemical into motive water.

Should not be used in systems where water pressure exceeds 4 BARS.

3/4" Fittings.
Add to Cart
R720.36
RO Tubing White
RO Tubing 1/4" (RO-TU14)
1/4" food-grade polyethylene tubing.
 
Typically used in the following systems:
  • Reverse Osmosis
  • Water Dispensers (Direct Connect)
  • Refrigerators with Water Dispensers
  • Aquarium Systems
  • Under-Counter Filtration Systems


Sold per meter.

Note: Coloured tubing varies between suppliers, maroon is sometimes supplied as red.

6.35mm OD
Add to Cart
R8.07
Ball Float Valve
Float Valve Small 1/8'' Female Thread (FVS)
Plastic float valve automatically start and stop water flow. The float is adjustable to allow you to control the water height.

Features & Specifications
  • Can be used vertically or horizontally.
  • 1/8" Female Thread.

Suitable for use with Reverse Osmosis Systems, Fish Aquariums, etc

* Requires 1/8" to 1/4" Tubing connector to attach 1/4" tubing, the optional fitting is available.

Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/8" is 9.9mm and 1/4" is 12.9mm.

Ball Float Valve.
Add to Cart
R67.59
RO Membrane Housing Wrench
RO Membrane Housing Wrench (HWM50)
Housing Wrench / Spanner for our 50GPD / 75GPD RO Membrane Housings.

Used to tighten and loosen filter housing when replacing membranes.
Used to tighten and loosen RO membrane housings.
Add to Cart
R42.00
RO Booster Pump Gi-An GMB78
RO Booster Pump for 100GPD RO + Transformer (ROBP2)

Used in domestic 50GPD or 100GPD reverse osmosis systems.

  • Diaphragm Pump.
  • Pump and Transformer Included.


Standard female 3/8" Inlet and Outlet.

Voltage: 24V DC
Current: 0.42A, (0.6A Max)
Open Flow: 58LPH (15.3GPH)
Medium: Water
Inlet Pressure: 0.2 MPa (29PSI) Min: 0.05 MPa (7.3PSI) Max: 0.4 MPa (58PSI).
Working Pressure: 0.56MPa (81PSI)
Working Flow: 28LPH (6.9GPH)
Bypass Pressure: 0.70MPa (100PSI) - 0.86MPa (125PSI) MAX
Temperature: 25C

Caution: Motor duty cycle will vary with load and ambient temperature.

24V DC Working: 28LPH 81PSI for 50-100GPD RO System including Transformer.
Add to Cart
R1,664.48
20
20" Standard Housing Wrench (HW002)
Housing Wrench / Spanner for our 20" Standard (Basic Blue) Housings.

Used to tighten and loosen filter housing when replacing cartridges.
Spanner to tighten and loosen filter housings.
Add to Cart
R42.00
Leak Detector
Leak Detector for Under-Counter Systems (ROLEAK)
Shuts off water supply when a leak is detected preventing water damage to cupboards.

This system works with any 10" Single, Dual or Triple Stage Under-Counter Filtration System or RO (Reverse Osmosis) System.

Standard 1/4" Inlet and Outlet.

The leaked-water accumulates in the holding tray and triggers shutoff of the supply.

*Does not include the RO system shown in the image.


Video Demonstration:


Automatically shuts off the water supply if a leak is detected.
Add to Cart
R402.50
RO Booster Pump
RO Booster Pump 24VDC (ROBP100)

Used in domestic 50GPD reverse osmosis systems.

  • Diaphragm Pump.
  • 3/8" Inlets


Pump only. Transformer not included but optional extra.
Tubing connectors will be required.
Advertised flow rates may vary slightly due to suppliers.

*Pump may differ to image as we have multiple suppliers.

Used in 50GPD-100GPD Systems.
Add to Cart
R867.20
Per Page      81 - 95 of 95