Reverse Osmosis Spares
RO Spares & Accessories
Reverse Osmosis Membrane Housing with flow restrictor and tubing connectors, pre-assembled.
Fits 50GPD, 75GPD, 100GPD and 125GPD membranes.
As shown in second image.
Reverse Osmosis Membrane Housing.
Fits 50GPD, 75GPD, 100GPD and 125GPD membranes.
Inlet, Permeate and Waste are all 1/8" Female Thread.
We recommend using the one-way check valve on the permeate to prevent reverse flow.
Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/8" is 9.9mm.
Reverse Osmosis Membrane Housing.
Fits 300GPD membranes.
We recommend using the one-way check valve on the permeate to prevent reverse flow.
*Product may differ slightly to image.
- Normally Closed.
*Note: The optional "1/4" Female Thread (Black) 15A" can be used with two of the 1/4" Thread to 3/8" Tubing Adapters for use with 300GPD and up RO units.
High flow booster pump with low energy consumption.
Technical specifications:
- Electrical connection: DC48V 2.3A
- Maximum operating pressure: 10.5 Bar
- Membrane: 2 x 200GPD or 1 x 400GPD
- Maximum output: 3.0 L/min.
- Model: HF 45L
*** May differ to images due to multiple suppliers.
This system works with any 10" Single, Dual or Triple Stage Under-Counter Filtration System or RO (Reverse Osmosis) System.
Standard 1/4" Inlet and Outlet.
The leaked-water accumulates in the holding tray and triggers shutoff of the supply.
*Does not include the RO system shown in the image.
Video Demonstration:
Used in under-counter RO systems.
- xxxML / minute restriction under normal conditions.
- 1/4" Female fittings.
Empty In-Line Housing with 1/4" Threads for use with Candle Filter Types.
Uses a rubber o-ring seal.
Can also be used as an empty housing for filter media (such as ion-exchange resin) if you use two sponges.
Not recommended where pressure may exceed 4 bars without using a pressure reducing valve.
Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/4" is 12.9mm.
Cap only which includes 2 rubber seals.
May differ from image due to multiple suppliers.
Automatically shuts off the water supply when the tank pressure (or permeate pressure) reaches ~65% of the incoming line pressure.
Without a shut-off block (or solenoid in case of RO with pump) the RO would be wasting water permanently even when the tank is full.
Cap only which includes 2 rubber seals.
Image shown is a 4040 end cap for illustration only.
Used in domestic RO systems.
Solenoid Valve 24V DC Normally Closed.
We have multiple suppliers for these so they may differ to the pictures.
Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/4" is 12.9mm.
Used in domestic 50GPD or 100GPD reverse osmosis systems.
- Diaphragm Pump.
- Pump and Transformer Included.
Standard female 3/8" Inlet and Outlet.
Voltage: 24V DC
Current: 0.42A, (0.6A Max)
Open Flow: 58LPH (15.3GPH)
Medium: Water
Inlet Pressure: 0.2 MPa (29PSI) Min: 0.05 MPa (7.3PSI) Max: 0.4 MPa (58PSI).
Working Pressure: 0.56MPa (81PSI)
Working Flow: 28LPH (6.9GPH)
Bypass Pressure: 0.70MPa (100PSI) - 0.86MPa (125PSI) MAX
Temperature: 25C
Caution: Motor duty cycle will vary with load and ambient temperature.
Used directly on copper pipe to attach 1/4" tubing for RO or under counter filtration systems without needing to cut the copper pipe or use additional tools or fittings.
The clamp is secured around the copper pipe and a needle-like fixture pierces the copper pipe to allow the water to flow out the 1/4" adapter where 1/4" tubing is attached.
The faucet can be turned to shut off flow also functioning as a shutoff valve.
Empty In-Line Housing with 1/4" Female Threads.
Can be filled and refilled with any filter media, mixed bed resin, carbon granules, mineral stones, etc...
Uses a rubber o-ring seal. Includes 2 sponges.
Not recommended where pressure may exceed 4 bars without using a pressure reducing valve.
Please Note: The thread fittings are not outer diameter measurements, the outer diameter measurement for 1/4" is 12.9mm.
- Body Material: Brass
- Pressure Max: 12 BAR
- Input: 220V AC
- Max Temperature: 80c
*** May differ to image due to multiple suppliers and models.
Used in under-counter RO systems.
- 400ML or 300ML / minute restriction under normal conditions.
- 1/4" Female fittings.
- Ball Valve built in for manual flushing.
Used in domestic 50GPD reverse osmosis systems.
- Diaphragm Pump.
- 3/8" Inlets
Pump only. Transformer not included but optional extra.
Tubing connectors will be required.
Advertised flow rates may vary slightly due to suppliers.
*Pump may differ to image as we have multiple suppliers.
Used directly on copper pipe to attach 1/4" tubing for RO or under counter filtration systems without needing to cut the copper pipe or use additional tools or fittings.
The clamp is secured around the copper pipe and a needle-like fixture pierces the copper pipe to allow the water to flow out the 1/4" adapter where 1/4" tubing is attached.
The faucet can be turned to shut off flow also functioning as a shutoff valve.
Fits both 15mm and 22mm copper pipes.
*actual product may differ slightly to image.