Search

Search Criteria

 
 
 
 

Products meeting the search criteria

Sort By:  
Industrial Reverse Osmosis Plant.
Add to Cart
R139,150.00
RO Filter Set
High quality complete set of 5 filters including Vontron RO Membrane.
Add to Cart
R805.00
RO 1500GPD
Industrial reverse osmosis plant.
Add to Cart
R85,008.00
RO for Marine with DI
Two stage RO with deionizer resin post filter for use with marine tanks.
Add to Cart
R2,218.29
Available in 3012 and 3013.
Add to Cart
R1,610.00
Automatic Shutoff Block for RO
Shuts off water supply when RO tank full.
Add to Cart
R89.80
Available in 3012 and 3013.
Add to Cart
R2,185.00
Reverse Osmosis Plant 6000GPD 22000LPD S/Steel (RO6000GPDSS)
  • 4 x 4040 Membranes.
  • 50% Recovery.

Weight is estimated.

Information available on request.

 

RO Plants such as these are usually only supplied when an analysis has been done on the raw water, without knowing what is in the water we cannot guarantee this plant will suite your needs. Pre-filtration likely will be required.

Industrial Reverse Osmosis Plant.
Add to Cart
R139,150.00
RO Filter Set
Reverse Osmosis Replacement Filter Set (ROSET)
Replacement cartridges for under-counter RO (Set of 5).

  • Stage 1 : Polypropylene Sediment Reduction Cartridge (MICROFIL 5um).
  • Stage 2 : Granular Activated Carbon Cartridge.
  • Stage 3 : Carbon Block Cartridge (5um).
  • Stage 4 : Reverse Osmosis Membrane.
  • Stage 5 : Post Carbon Cartridge (T33).

This set fits standard under-counter reverse osmosis systems.
 
Actual filters in the set may not be identical to the ones in the picture above due to multiple suppliers.

High quality complete set of 5 filters including Vontron RO Membrane.
Add to Cart
R805.00
Vontron ULP1812 Membrane
VONTRON 75GPD Reverse Osmosis Membrane (RO-M75GPDV)
Vontron ULP1812-75 Reverse Osmosis Membrane.
 
This membrane is rated at 75 Gallons per day (280 litres per day).
  • Fits in standard 1.8" x 12" residential RO membrane housings.
 

VONTRON® Residential Membrane Elements

Brief Introduction

The 1812-sized and 2012-sized residential membrane elements are mainly applicable to various small-sized systems, such as household water purifier and other water purifying devices in hospital and laboratory.
Being suitable for the desalting treatment of those water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series are mainly applicable to numerous applications of various sizes, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.

Specifications and Major Properties

Active Membrane Area ft²(m²): 3.5(0.32)
Average Permeated Flow: 75 GPD
Stable Rejection Rate: 97.5%
Minimum Rejection Rate: 96.0%

Testing Conditions:

Testing Pressure 60 psi (0.41Mpa)
Temperature of Testing Solution 25°C
Concentration of Testing Solution (NaCl) 250ppm
pH Value of Testing Solution 7.5
Recovery Rate of Single Membrane Element 15%
 
 

Extreme Operation Conditions:

Max. Working Pressure: 300psi(2.07Mpa)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Free Chlorine Concentration of Feedwater <0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 10psi(0.07Mpa)
 

Important Information

1.         Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, Vontron technology Co., Ltd. will assume no liability for all results.

2.         The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding ±20% of the nominal value.

3.        All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanediol required in winter) for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation and system standby, we recommend you to soak the membrane elements with protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfite (foodstuff-purpose).

4.       Discard the RO-filtered water produced during the first one hour after system start-up.

5.        During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful.
 
High quality RO membrane.
Add to Cart
R493.35
Post DI
Post Deionizing Filter for Reverse Osmosis (RO-PR)
This filter will deionize RO water to reduce the TDS to near zero.
  • Contains Mixed-Bed Resin.
  • Media can be regenerated manually with salt.
  • 1/4" Female fittings on ends.
  • Reusable: Can be refilled.
Deionized water is similar to Distilled.

This filter is installed after the RO process before the tank or in-line to the faucet.

Recommended to be used on RO systems with a TDS under 15. We cannot confirm if the TDS will be zero after if the TDS from the RO is over 10.
Reusable Ion Exchange Filter.
Add to Cart
R220.80
Vontron 4040
VONTRON ULP21-4040 Reverse Osmosis Membrane (RO-MEMULP2)
Specifications
  • Model: ULP21-4040 
  • Reject: 99.0%
  • Average Permeate GPD(m3/d): 2400(9.1) 
  • Active Membrane Area ft2(m2): 90(8.4) 
 
Brief Introduction
 
ULP series of ultra-low pressure aromatic polyamide compound membrane element newly developed by Vontron Technology Co. Ltd.
 
Membrane can operate under ultra low pressure to reach as high permeate flow and salt rejection as regular low-pressure membrane element can and is applicable to desalination of surface water and underground water.
 
It operates under approximately 2 thirds of the operating pressure of regular low-pressure composite membranes, and achieves a salt rejection rate of up to 99.5%, which can decrease the investment costs for relevant facilities such as pumps, piping and the operating cost for the RO system, thus increasing the economic efficiency.
 
Being suitable for the desalting treatment of those water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series membrane elements are mainly applicable to numerous applications of various scales, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.
 
High quality 4040 RO membrane.
Add to Cart
R4,993.43
Reverse Osmosis System 400GPD
Reverse Osmosis System 400GPD 1500LPD (RO400GPD)
Reverse Osmosis is a process where water is demineralised using a semi permeable membrane at high pressure. Your normal filtration units will only reduce certain contaminants such as silt, rust, chlorine and bacteria (up to 96%). Reverse Osmosis machines will purify your water up to 99.9% or 0.001 microns, thus removing other dissolved contaminants like Colloid, lead, mercury, germs and other metals.

Stage 1 : Polypropylene Cartridge – 5 Micron Superfine Filter – Removes solid particles & impurities i.e. silt & rust.
Stage 2 : Granular Activated Carbon (UDF) Filter – Absorbs odours, chemicals & chlorine.
Stage 3 : Carbon Block Filter (CTO) – removes additional chlorine & water decolourants.
Stage 4 : Reverse Osmoses Membranes – Removes up to 0.0001 microns colloid, metals, germs & bacteria.
Stage 5 : Post Carbon Filter (T33) – improves water taste.

If your water pressure is above 6 bar you will need a pressure reducing valve to keep your pressure within the operating pressure limits.
 
  • This unit produces up to 400 Gallons or 1500 litres every 24 hours.
  • This unit has two pumps, an electrical outlet is required nearby.
  • This unit has four VONTRON 100GPD membranes.
  • This unit includes a 40LT RO Storage Tank and a Standard Elegant RO Faucet (not shown in picture).
  • This unit can be modified with a float switch to fill up larger tanks, such as JoJo Tanks, as seen in this photo.

We recommend that a plumber install the unit as a pressure reducing valve may be required.

You can replace the 100GPD membranes with 125GPD membranes to get up to 500GPD/1900LPD from this unit.
Add to Cart
R17,825.00
RO 1500GPD
Reverse Osmosis Plant 1500GPD 5600LPD S/Steel (RO1500GPD)
  • 1 x 4040 Membrane.
  • 50% Recovery.

Weight is estimated.

Information available on request.

RO Plants such as these are usually only supplied when an analysis has been done on the raw water, without knowing what is in the water we cannot guarantee this plant will suite your needs. Pre-filtration most likely will be needed.

Industrial reverse osmosis plant.
Add to Cart
R85,008.00
Vontron ULP1812 Membrane
VONTRON 50GPD Reverse Osmosis Membrane (RO-M50GPDV)
Vontron ULP1812-50 Reverse Osmosis Membrane.
 
This membrane is rated at 50 Gallons per day (180 litres per day).
  • Fits in standard 1.8" x 12" residential RO membrane housings.
 

VONTRON® Residential Membrane Elements

Brief Introduction

The 1812-sized and 2012-sized residential membrane elements are mainly applicable to various small-sized systems, such as household water purifier and other water purifying devices in hospital and laboratory.
Being suitable for the desalting treatment of those water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series are mainly applicable to numerous applications of various sizes, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.

Specifications and Major Properties

Active Membrane Area ft²(m²): 3.5(0.32)
Average Permeated Flow: 50 GPD
Stable Rejection Rate: 97.5%
Minimum Rejection Rate: 96.0%

Testing Conditions:

Testing Pressure 60 psi (0.41Mpa)
Temperature of Testing Solution 25°C
Concentration of Testing Solution (NaCl) 250ppm
pH Value of Testing Solution 7.5
Recovery Rate of Single Membrane Element 15%
 
 

Extreme Operation Conditions:

Max. Working Pressure: 300psi(2.07Mpa)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Free Chlorine Concentration of Feedwater <0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 10psi(0.07Mpa)
 

Important Information

1.         Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, Vontron technology Co., Ltd. will assume no liability for all results.

2.         The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding ±20% of the nominal value.

3.        All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanediol required in winter) for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation and system standby, we recommend you to soak the membrane elements with protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfite (foodstuff-purpose).

4.       Discard the RO-filtered water produced during the first one hour after system start-up.

5.        During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful.
 
High quality RO membrane.
Add to Cart
R414.00
RO for Marine with DI
Reverse Osmosis for Marine Aquarium with DI Resin (DUCFROM)

Reverse Osmosis is a process where water is demineralised using a semi permeable membrane at high pressure. Your normal filtration units will only reduce certain contaminants such as silt, rust, chlorine and bacteria (up to 96%). Reverse Osmosis machines will purify your water up to 99.9% or 0.001 microns, thus removing other dissolved contaminants like Colloid, lead, mercury, germs and other metals.

 

Stage 1 : Polypropylene Cartridge – 5 Micron Superfine Filter – Removes solid particles & impurities i.e. silt & rust.

Stage 2 : Granular Activated Carbon (UDF) Filter – Absorbs odours, chemicals & chlorine.

Stage 3 : Reverse Osmoses Membrane – Removes up to 0.0001 microns colloid, metals, germs & bacteria.

Stage 4 : DI Resin – Deionizer post filter to reduce TDS further.

 

Operating Pressure: 50 - 100 psi (3.5 to 6.5 bar)

 
If your water pressure is bellow 3.5 bar you will require an RO with a pump.
If your water pressure is above 6 bar you will need a pressure reducing valve to keep your pressure within the operating pressure limits.

 

This unit produces up to 50 Gallons or 190 litres every 24 hours (up to 130ml/minute).

This unit does not include a pump, no electricity required.
 

This unit does not include automatic shutoff, a tank or faucet, you get what is in the picture plus 1M of RO tubing and a ball valve and ball valve adapter to connect to the mains and a housing wrench.

All options purchased include assembly onto the main unit where applicable.

Two stage RO with deionizer resin post filter for use with marine tanks.
Add to Cart
R2,218.29
300GPD Reverse Osmosis Membrane (RO-MEM300)
Due to multiple suppliers and brands we can not list the specifications, they are used in domestic 300GPD and 400GPD RO systems, be sure to select the correct housing size 3012 or 3013. Confirm the size by checking the model number of your previous membrane.
Available in 3012 and 3013.
Add to Cart
R1,610.00
Reverse Osmosis with Pump
Reverse Osmosis System 50GPD 189LPD with Pump (RO50GPDP)

Reverse Osmosis is a process where water is demineralised using a semi permeable membrane at high pressure. Your normal filtration units will only reduce certain contaminants such as silt, rust, chlorine and bacteria (up to 96%). Reverse Osmosis machines will purify your water up to 99.9% or 0.001 microns, thus removing other dissolved contaminants like Colloid, lead, mercury, germs and other metals.

 

Stage 1 : Polypropylene Cartridge – 5 Micron Superfine Filter – Removes solid particles & impurities i.e. silt & rust.

Stage 2 : Granular Activated Carbon (UDF) Filter – Absorbs odours, chemicals & chlorine.

Stage 3 : Carbon Block Filter (CTO) – removes additional chlorine & water decolourants.

Stage 4 : Reverse Osmoses Membrane – Removes up to 0.0001 microns colloid, metals, germs & bacteria.

Stage 5 : Post Carbon Filter (T33) – improves water taste.


Faucet and all necessary installation fittings are included.

Operating Pressure: 50 - 100 psi (3.5 to 6.5 bar)

If your water pressure is above 6 bar you will need a pressure reducing valve to keep your pressure within the operating pressure limits.

This unit produces up to 50 Gallons (189 litres) every 24 hours.

10L Storage tank is included but not shown in picture.

This unit has a pump, an electrical outlet is required nearby.


We recommend that a plumber install the unit as a pressure reducing valve may be required.

Add to Cart
R3,255.31
Automatic Shutoff Block for RO
Automatic Shut Off Block for Reverse Osmosis (RO-ASOV)
Available in 1/4" with quick connect and 3/8" with compression nuts (see pictures).

Automatically shuts off the water supply when the tank pressure (or permeate pressure) reaches ~65% of the incoming line pressure.

Without a shut-off block (or solenoid in case of RO with pump) the RO would be wasting water permanently even when the tank is full.
Shuts off water supply when RO tank full.
Add to Cart
R89.80
400GPD Reverse Osmosis Membrane (RO-MEM400)
Due to multiple suppliers and brands we can not list the specifications, they are used in domestic 300GPD and 400GPD RO systems, be sure to select the correct housing size 3012 or 3013. Confirm the size by checking the model number of your previous membrane.
Available in 3012 and 3013.
Add to Cart
R2,185.00
Reverse Osmosis System without pump (RO50GPD)

Reverse Osmosis is a process where water is demineralised using a semi permeable membrane at high pressure. Your normal filtration units will only reduce certain contaminants such as silt, rust, chlorine and bacteria (up to 96%). Reverse Osmosis machines will purify your water up to 99.9% or 0.001 microns, thus removing other dissolved contaminants like Colloid, lead, mercury, germs and other metals.

 

Stage 1 : Polypropylene Cartridge – 5 Micron Superfine Filter – Removes solid particles & impurities i.e. silt & rust.

Stage 2 : Granular Activated Carbon (UDF) Filter – Absorbs odours, chemicals & chlorine.

Stage 3 : Carbon Block Filter (CTO) – removes additional chlorine & water decolourants.

Stage 4 : Reverse Osmoses Membrane – Removes up to 0.0001 microns colloid, metals, germs & bacteria.

Stage 5 : Post Carbon Filter (T33) – improves water taste.


Faucet and all necessary installation fittings are included.

Operating Pressure: 50 - 100 psi (3.5 to 6.5 bar)

If your water pressure is above 6 BAR you will need a pressure reducing valve to keep your pressure within the operating pressure limits.

If your water pressure is below 3.5 BAR the RO will not produce any water, in this case you need the RO with a booster pump, if unsure you should rather buy the RO with the pump.

This unit produces up to 50 Gallons (189 litres) every 24 hours where water pressure is at least 5 BAR.

10L Storage tank.

This unit does not have a pump and does not use electricity.


We recommend that a plumber install the unit as a pressure reducing valve may be required.


*Unit may differ to image due to multiple suppliers.

Add to Cart
R2,645.00
Vontron ULP1812 Membrane
VONTRON 100GPD Reverse Osmosis Membrane (RO-MEM100)
VONTRON® Residential Membrane Elements
Brief Introduction
The 1812-sized residential membrane elements are mainly applicable to various small-sized systems, such as household water purifiers and other water purifying devices in hospitals and laboratories.
 Being suitable for desalinization systems and water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series are mainly applicable to numerous applications of various sizes, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.
 
Specifications and Major Properties
Model
Active Membrane Area
ft2(m2)
Average Permeated Flow
GPD (m3/d)
Stable Rejection Rate (%)
Minimum Rejection Rate (%)
ULP1812-50
3.5(0.32)
50(0.19)
97.5
96.0
ULP1812-75
4.2(0.38)
75(0.28)
97.5
96.0
ULP1812-100
5.0(0.46)
100(0.38)
95.0
93.0
 
Testing Conditions:  Testing Pressure…………………………………60 psi (0.41Mpa)
                                     Temperature of Testing Solution …………..…25 ℃
                                     Concentration of Testing Solution (NaCl)…….. 250ppm
                                     pH Value of Testing Solution ……………….….7.5
                                     Recovery Rate of Single Membrane Element….15%
Extreme Operation Conditions
Max. Working Pressure…………………...…….……….  300psi(2.07Mpa)
Max. Feedwater Temperature…………………….………   45℃
Max. Feedwater SDI………………….………………….. 5
Free Chlorine Concentration of Feedwater………………     <0.1ppm
pH Range of Feedwater during Continuous Operation…..      3~10
pH Range of Feedwater during Chemical Cleaning……...      2~12
Max. Pressure Drop of Single Membrane Element…….        10psi(0.07Mpa)
 
Sizes are in mm (inch in brackets).
 
Important Information
1.         Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, Vontron technology Co., Ltd. will assume no liability for all results.
2.         The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding ±20% of the nominal value.
3.        All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanediol required in winter) for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation and system standby, we recommend you to soak the membrane elements with protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfite (foodstuff-purpose).
4.       Discard the RO-filtered water produced during the first one hour after system start-up.
5.       During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful<

 

1812 Size.
Add to Cart
R569.25
Per Page      1 - 15 of 15